Application
• Nelson’s Type HLT self-regulating heater cable is ideal for maintaining flow over a wide range of operating temperatures.
• The product is used for available for freeze protection of periodically steam (200 psig) cleaned pipes and temperature
• maintenance for 121°C (250°F) or lower processes.
• Typical applications include hydrocarbon and chemical product piping.

Nelson’s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated, 16-gauge copper bus wires. A fluoropolymer jacket provides excellent dielectric strength, moisture resistance, protection from impact and abrasion damage, and a wide range of chemical resistance. A stranded tinned copper metal braid is supplied on all heaters. An optional fluoropolymer over jacket can be specified when the heater cable is to be installed in wet or corrosive environments. The base product is supplied with a tinned copper metal braid that may be used in both general applications and in dry, noncorrosive hazardous (classified) areas.

Suffix:
• -CB Tinned Copper Braid
• -J Tinned Copper Braid & Fluoropolymer Over Jacket
• -WJ Monitor Wire, Braid & Jacket (MINIMUM ORDER QUANTITY 1000FT)
• -SS Stainless Steel Braid (MINIMUM ORDER QUANTITY 1000FT)

NOTES:
1. Circuit breakers are sized per national electrical codes and are based on start-up temperatures between -20°F (-29°C) and 50°F (10°C).
2. When using 240 volt product at 208, 220 or 277 volts, use the circuit adjustment factors shown in the Voltage Adjustment Table.
3. When using 2 or more heater cables of different wattage ratings in parallel on a single circuit breaker, use the 15A column amperage of 15 amps, divide it by the maximum footage to arrive at an amps/foot figure for each cable. You can then calculate circuit breaker sizes for these combination loads. These amps/foot factors include the 125% sizing factor.
4. National electrical codes require ground-fault equipment protection for each branch circuit supplying electric heating equipment. Exceptions to this requirement can be found in the 2002 N.E.C.
5. Heater cables with D1 -optional construction require the use of a ground fault interrupter/ground leakage device with a trip setting no greater than 30mA.













HLT Self-Regulating Heater Cable Specification Sheet
HLT 230V Self-Regulating Heater Cable Specification Sheet
Self Regulating Cable Manual
  »Results Page:  1  2 
Item IDDescriptionQuantity
D1-HLT10
SRHC HLT 10W 120V Division 1 Self-Regulating Heater Cable, Wattage: 10, Service Voltage: 120, Jacket: Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT10-CB
SRHC HLT 10W 120V w/Copper BraidSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 120, Jacket: Copper Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT10-J
SRHC HLT 10W 120V w/Jacket Over Metal Braid Self-Regulating Heater Cable, Wattage: 10, Service Voltage: 120, Jacket: Fluoropolymer Jacket Over Metal Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT10W-J
SRHC HLT 10W 120V w/Monitor Wire, Braidand JacketSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 120, Jacket: Monitor Wire, Braid and Jacket, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT10-SS
SRHC HLT 10W 120V w/Stainless Steel BraidSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 120, Jacket: Stainless Steel Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
D1-HLT210
SRHC HLT 10W 240V Division 1 Self-Regulating Heater Cable, Wattage: 10, Service Voltage: 240, Jacket: Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT210-CB
SRHC HLT 10W 240V w/Copper BraidSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 240, Jacket: Copper Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT210-J
SRHC HLT 10W 240V w/Jacket Over Metal BraidSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 240, Jacket: Fluoropolymer Jacket Over Metal Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT210W-J
SRHC HLT 10W 240V w/Monitor Wire, Braidand JacketSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 240, Jacket: Monitor Wire, Braid and Jacket, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT210-SS
SRHC HLT 10W 240V w/Stainless Steel BraidSelf-Regulating Heater Cable, Wattage: 10, Service Voltage: 240, Jacket: Stainless Steel Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
D1-HLT15
SRHC HLT 15W 120V Division 1 Self-Regulating Heater Cable, Wattage: 15, Service Voltage: 120, Jacket: Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT15-CB
SRHC HLT 15W 120V w/Copper BraidSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 120, Jacket: Copper Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT15-J
SRHC HLT 15W 120V w/Jacket Over Metal BraidSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 120, Jacket: Fluoropolymer Jacket Over Metal Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT15W-J
SRHC HLT 15W 120V w/Monitor Wire, Braidand JacketSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 120, Jacket: Monitor Wire, Braid and Jacket, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT15-SS
SRHC HLT 15W 120V w/Stainless Steel BraidSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 120, Jacket: Stainless Steel Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
D1-HLT215
SRHC HLT 15W 240V Division 1 Self-Regulating Heater Cable, Wattage: 15, Service Voltage: 240, Jacket: Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT215-CB
SRHC HLT 15W 240V w/Copper BraidSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 240, Jacket: Copper Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT215-J
SRHC HLT 15W 240V w/Jacket Over Metal Braid Self-Regulating Heater Cable, Wattage: 15, Service Voltage: 240, Jacket: Fluoropolymer Jacket Over Metal Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT215W-J
SRHC HLT 15W 240V w/Monitor Wire, Braidand JacketSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 240, Jacket: Monitor Wire, Braid and Jacket, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3
HLT215-SS
SRHC HLT 15W 240V w/Stainless Steel BraidSelf-Regulating Heater Cable, Wattage: 15, Service Voltage: 240, Jacket: Stainless Steel Braid, Max Maintenance Temp: 250°F (121°C), Max Intermittent Exposure: 420°F (215°C), T-Rating: T3